🔍

Purchase the full subscription package now and enjoy a 40% discount, along with free updates for future editions.
AS/NZS 3580.9.15:2014
$109.95
Methods for sampling and analysis of ambient air, Method 9.15: Determination of suspended particulate matter — Particulate metals high or low volume sampler gravimetric collection — Inductively coupled plasma (ICP) spectrometric method
This Standard sets out a method for the c determination of particulate metals collected from ambient air by either a high or low volume sampler and analysed by inductively coupled plasma/mass spectrometry (ICP-MS).
Table of contents
Header
About this publication
Preface
Foreword
1 Scope
2 Referenced documents
3 Definitions
4 Principle
5 Safety precautions
6 Reagents
6.1 General requirements
6.2 Concentrated hydrochloric acid (HCl)
6.3 Concentrated nitric acid (HNO3)
6.4 Nitric acid (HNO3) for cleaning solution
6.5 Solutions
6.5.1 General
6.5.2 Metals extraction solution (16% HCl/6% HNO3)
6.5.3 Diluent for working solutions preparation/rinse blank solution (2% HNO3)
6.5.4 Nitric acid cleaning solution (5% HNO3)
6.5.5 Calibration blank solution (1% HNO3)
6.6 Stock standard solutions
6.7 Working solutions
6.7.1 Calibration standard solutions
6.7.2 Calibration check solutions
6.7.3 Instrument optimization solution
6.7.4 Internal standards solution
6.7.5 Interference check solution
6.7.6 Standardizing solutions
6.8 Argon
6.9 Certified reference material (CRM)
7 Apparatus
7.1 Filters
7.2 Filter cutter
7.3 Laboratory ware
7.4 Hotplate or dry block heater
7.5 Automatic dispensing pipettes (optional)
7.6 Inductively coupled plasma/atomic emission spectrometer
7.7 Inductively coupled plasma/mass spectrometer
7.8 Auto-sampler (optional)
8 Sampling
9 Procedure
9.1 Filter metals extraction
9.1.1 General
9.1.2 Preparation of filter sample
9.1.3 Preparation of test sample solution
9.2 Preparation of quality control solutions
9.2.1 General
9.2.2 Laboratory blank filter solution
9.2.3 Field blank filter solution
9.2.4 Reagent blank solution
9.2.5 Method quality control solution
9.3 Analysis
9.3.1 General
9.3.2 Method development
9.3.3 Pre-analysis instrument procedures
9.3.3.1 Instrument set-up
9.3.3.2 Performance checks
9.3.3.3 Interference check
9.3.4 Analysis
9.3.4.1 General
9.3.4.2 Calibration
9.3.4.3 Measurement of test and blank samples
10 Quality assurance
10.1 General
10.2 Calibration check
10.3 Quality control solutions
10.4 Recovery rate check
10.5 Interference check
10.6 Field blank filter check
11 Calculations
11.1 General
11.2 Calculation of the mass of metal on the filter
11.3 Calculation of the average mass of metal on the laboratory blank filter
11.4 Calculation of the metal concentration in ambient air
12 Measurement uncertainty
13 Test report
Cited references in this standard
Please select a variation to view its description.
| Published | 19/12/2014 |
|---|---|
| Pages | 15 |
Please select a variation to view its pdf.


